Effect of fluoroscopy frame rate on radiation exposure and in‐hospital outcomes in three‐dimensional electroanatomic mapping guided procedures

Muzaffar Ali; Deepak Padmanabhan; Khalil Kanjwal; Milan Kumar Ghadei; Anju Kottayan; Bharatraj Banavalikar; Jayaprakash Shenthar · 2021 · Journal of Arrhythmia

WASTE classifies this as Negative / Null Result Report · AI classification, approximate

The study found no significant effect — useful as a negative control or null benchmark for your own design.

Abstract

Abstract Background Fluoroscopic imaging involves exposure of the patients and the laboratory staff to ionizing radiation. One of the strategies that reduce such exposure in an electrophysiology laboratory is using a three‐dimensional electroanatomic mapping (3D EAM) system for performing these procedures. In this analysis, we have analyzed the effect of fluoroscopy frame rate on the radiation exposure and in‐hospital outcomes in ablation procedures performed under 3D EAM guidance. Methods We retrospectively analyzed all the ablation procedures performed under 3D EAM guidance at our institute

Abstract by Muzaffar Ali; Deepak Padmanabhan; Khalil Kanjwal; Milan Kumar Ghadei; Anju Kottayan; Bharatraj Banavalikar; Jayaprakash Shenthar, Journal of Arrhythmia (2021) — licensed CC BY 4.0.